Choose a different region to see content for your location
ALUCOBOND® A2 is our non-combustible aluminium composite panel used in architecture that fulfills the respective standards worldwide. Thanks to its mineral-filled core, ALUCOBOND® A2 meets the strict requirements of the fire regulations and enhances the possibilities for the concept and design of buildings. ALUCOBOND® A2, just like all the products of the ALUCOBOND® family, allows simple processing, is impact-resistant, break-proof and weatherproof and, above all, non-combustible.
ALUCOBOND® A2 compared with solid aluminium
Required thickness and actual weights of panels with same rigidity
ALUCOBOND® A2 | Aluminium | ||||
Rigidity (E·I) | Section modulus | Thickness | Weight | Thickness | Weight |
1250 kN cm²/m | 1.25 cm³/m | 3 mm | 5.9 kg/m² | 2.7 mm | 7.3 kg/m² |
2400 kN cm²/m | 1.75 cm³/m | 4 mm | 7.6 kg/m² | 3.3 mm | 8.9 kg/m² |
ALUCOBOND® A2
Thickness: 3/4mm
Width [mm] | 1000 | 1250 | 1500 | 1575 | 1650 |
---|---|---|---|---|---|
Length [mm] | 2000-6800 | 2000-6800 | 2000-6800 | 2000-6800 | 2000-6800 |
Solid Colours | ![]() |
![]() |
![]() |
||
Metallic Colours | ![]() |
![]() |
![]() |
||
Spectra & sparkling | ![]() |
||||
Anodized Look | ![]() |
![]() |
![]() |
||
NaturAL * | ![]() |
![]() |
|||
ALUCOBOND® legno – premium wood | ![]() |
![]() |
|||
Vintage | ![]() |
![]() |
|||
Façade design – individual décor | ![]() |
![]() |
|||
Urban | ![]() |
![]() |
|||
Terra | ![]() |
![]() |
|||
Rocca | ![]() |
![]() |
|||
Mill Finish | ![]() |
![]() |
on request
* Exception: ALUCOBOND® naturAL Reflect is only available in ALUCOBOND® PLUS in width 1250 mm.
Dimensional Tolerances (Standard)
Due to manufacturing, a displacement of the cover sheets sidewise at the panel edges up to 2 mm is possible.
Thickness: ± 0,2 mm
(mill-finish | stove lacquered | anodized)
Width: - 0 / + 4 mm
Lengths: 2000 - 4000 mm; - 0 / + 6 mm
Lengths: 4001 - 6800 mm; - 0 / + 10 mm
Colours and surfaces
More colours and surfaces are available upon request.
They are subject to our minimum quantities.
Thickness | Standards | Unit | 3 mm | 4 mm | |
Thickness of Aluminium Layers |
[mm] | 0.5 | |||
Weight | [kg/m²] | 5.9 | 7.6 | ||
Width | [mm] | 1250 / 1500 | |||
Technical properties | |||||
Section modulus | W | DIN 53293 | [cm³/m] | 1.25 | 1.75 |
Rigidity | E·J | DIN 53293 | [kNcm²/m] | 1250 | 2400 |
Alloy / Temper of Aluminium Layers |
EN 573-3 EN 515 |
EN AW 5005A (AIMg1) H22 / H42 |
|||
Modulus of Elasticity | EN 1999 1-1 | [N/mm²] | 70'000 | ||
Tensile Strength of Aluminium | EN 485-2 | [N/mm²] | Rm ≥ 130 | ||
0.2 % Proof Stress | EN 485-2 | [N/mm²] | Rp0,2 ≥ 90 | ||
Elongation | EN 485-2 | [%] | A50 ≥ 5 | ||
Linear Thermal Expansion |
EN 1999 1-1 | 2.4 mm/m at 100 K temperature difference | |||
Core | |||||
Mineral-filled core with polymer adhesives |
|||||
Surface | |||||
Lacquering | High-grade polymer coating system applied in coil coating | ||||
Acoustical Properties | |||||
Sound Absorption Factor | αs | ISO 354 | 0.05 | ||
Sound Transmission Loss | Rw | ISO 717-1 | [dB] | 27 | 27 |
Loss Factor | d | EN ISO 6721, Frequency range 100-3200 Hz |
0.004 | 0.005 | |
Thermal Properties | |||||
Thermal Resistance | R | DIN 52612 | [m²K/W] | 0.002 | 0.002 |
Thermal conductivity | λ | DIN 52612 | [W/mK] | 1.99 | 1.77 |
Heat Transition Coefficient | U | DIN 52612 | [W/m²K] | 5.83 | 5.80 |
Temperature Resistance | [ºC] | -50 to +80 | |||
Wind load and permissible panel sizes
In Germany, the dimensioning of ALUCOBOND® façade systems is regulated by the general building inspectorate approval (abZ) No. Z-10.3-774. In the Technical Extras section, you can find this and other documents, including load tables, dimensioning aids and various design examples
Country | Test accord. to ... | Classification |
EU | EN 13501-1 | Class A2-s1, d0 |
Germany | EN 1187 (method 1) / DIN 4102-7 |
passed |
Great Britain England / Wales / Scotland |
BR 135 | meets requirements of LUL |
Switzerland | VKF | RF1 |
Poland | EN 13501-1 | Class A2-s1, d0 |
Russia | GOST 30244-94 GOST 30402-95 GOST 12.1.044-89 GOST 12.1.044-89 |
G1 (combustibility) W1 (flammability) D1 (smoke development) T1 (toxicity) |
Australia | AS ISO 9705 AS 1530.3 Indices EN 13501-1 |
Group 1 material SMOGR A 0.630 m2 / s2 0 (ignitibility) 0 (flame spread) 0 (heat evolved) 0-1 (smoke development) A2-s1, d0 |
Country | Large fire testing |
Classification |
Austria | ÖNORM B 3800-5 | passed |
France | Lepir 2 | passed |
Hungary | MSZ 14800-6 | passed |
Great Britain | BS 8414 part 1 & 2 | passed |
Poland | According to ITB guidelines | passed |
Russia | GOST 31251 | passed |